SPECIFICATIONS:
Display: " high 4 digit LCD
Range: –40 to 2000°F (Fahrenheit Model)
–40 to 1200°C (Celsius Model)
Accuracy Chart:
Resolution:
Update Rate: Less than 1 second
Probes: Ultra-fast response, naked bead type K thermocouple
Case: ABS plastic
Fail safe: Low battery indicator
Power: 9 volt alkaline battery
Accessories
supplied: Integrated stand and PVC pouch with carrying strap
PROBE
The probes supplied are ultra-fast response, naked bead type K
thermocouples. Operating temperature range for this thermocouple is
the 482°F (250°C), and short term usage to 572°F (300°C). Accessory
probes are available for measuring temperatures throughout the entire
range of this unit. (See Accessories)
Longer leads and extensions may be used. The lead effect for 164 feet
(50 meters) is generally less than 0.2°C with a limit of error of 2.2°C.
Type K wire and type K connectors must be used.
OPERATION
Insert the sensor plug into the socket (T1 or T2). The plug and socket
are keyed with a small and large pin. Make certain the plug is inserted
correctly, do not insert the plug incorrectly and force it.
Slide the OFF/T1/T2 switch to T1 to display the temperature of T1, or
to T2 to display the temperature of T2. If there is no probe (an open
condition) the display will indicate 1 on the left side.
Place the probe tip in contact with the material to be measured and
read the temperature on the display.
Slide the OFF/T1/T2 switch to OFF to turn the unit off. To conserve
battery life, always turn the unit off when not in use.
ACCESSORIES
Control Cat. No. 4014–
Stainless Steel Triple Purpose Probe, probe diameter ⅛″ (0.32 cm),
probe length 6″ (15.2 cm), overall length 9″ (22.9 cm), cable length 50″
(127 cm).
Control Cat. No. 4008–
Surface Probe, flat disk on end has diameter of 0.39″ (1 cm), overall
length 9″ (23 cm), cable length 36″ (91.4 cm).
Control Cat. No. 4028–
Ultra-fast response, naked bead thermocouple, (identical to probe
supplied with unit) cable length 48″ (122 cm).
ALL OPERATIONAL DIFFICULTIES
If this thermometer does not function properly for any reason, please
replace the battery with a new high quality battery (see “Battery
Replacement section). Low battery power can occasionally cause any
number of “apparent” operational difficulties. replacing the battery with
anew fresh battery will solve difficulties
BATTERY REPLACEMENT
LO BAT appearing on the display indicates that the battery should be
replaced. To replace the battery, slide the battery cover, located on the
back of the unit, in the directions of the arrow (away from the
instrument). Remove the exhausted battery and replace it with a new 9
volt alkaline battery. Replace the battery cover.
WARRANTY, SERVICE, OR RECALIBRATION
For warranty, service, or recalibration, contact:
CONTROL COMPANY
4455 Rex Road
Friendswood, Texas 77546 USA
Ph. 281-482-1714 Fax 281-482-9448
www.control3.com
TRACEABLE
®
EXPANDED
-
RANGE THER
MOMETER INSTRUCTIONS
Vue de la page 0
1 2

Résumé du contenu

Page 1

Traceable® is a registered trademark of Control Company ©2008 Control Company. 92-4025-10 Rev. 3 051908 SPECIFICATIONS: Display: ⅝" hig

Page 2 - Traceable

Traceable® is a registered trademark of Control Company ©2008 Control Company. 92-4025-10 Rev. 3 051908 Control Company is ISO 9001 Quality-Certi

Commentaires sur ces manuels

Pas de commentaire