Traceable
®
is a registered trademark of Control Company ©2008 Control Company. 92-5058-00 Rev. 2 051908
SPECIFICATIONS
Power: 120 VAC, 60 HZ, 3-pronged grounded plug
Switching Capability: 120 VAC, 60 Hz, 1800 watts, 15 amps,
1/3 horsepower
Timing Accuracy: 0.01%
Timing Ranges: Repeat ON/OFF – 1 hour to 99 hours (H)
1 minute to 99 minutes (M)
1 second to 99 seconds (S)
Display: ½-inch (1.3 cm) LCD with backlighting
Size: 6 x 2¾ x 3¼ inches
Weight: 12 oz.
Case: High-impact, ABS plastic
Cat. No.: 5058 – Traceable
®
Repeat Walkaway™ Controller
NOTE: Remove clear plastic COVER by gently lifting one edge with a
paper clip before programming unit. If there is a clear plastic film
over face plate, remove and discard. Use COVER to protect
against accidental setting changes during timings and to protect
keys when unit is not in use.
NOTE: Receptacle outlet on back of unit has power only during count up
ON timing.
DIGITAL DISPLAY AND LIGHTS
1.
Steady red light on case indicates controller is receiving power.
2.
Flashing red lights indicates ON/OFF timing is in progress.
3.
HMS switch above red light sets timing hours H, minutes M, or seconds
S.
4.
Yellow PAUSE button pauses timing.
5.
Blue START/STOP button starts/stops timing.
6.
Blue buttons SET, 4/3, 2/1 set hours, minutes, or seconds for desired
programmed time.
7.
Blue RST button resets unit and returns display to 00.00.
LCD display is divided into four areas:
A.
Displays programmed ON time
B.
Displays elapsed count up ON time
C.
Displays programmed OFF time
D.
Displays elapsed count up OFF time
OPERATION
1.
Plug unit into power source. Red light will turn on.
2.
Plug desired equipment into receptacle outlet on back of unit.
3.
Remove clear plastic cover by gently lifting one edge with a paper clip.
4.
To return display to 00.00, gently press RST with a stylus or the end of
a bent paper clip. Or, move HMS switch to another position and then
back to desired setting. (Example: HMS switch is set at H. Move switch
to M and then back to H. Display will return to 00.00.)
5.
Move HMS switch to desired time using a stylus or the end of a bent
paper clip – hours (H appears on display), minutes (M appears on
display), or seconds (S appears on display).
6.
Press and hold SET button for three seconds. Display will flash.
7.
Press 4 and 3 to set desired ON time. Press and hold button to
advance setting rapidly.
8.
Press 2 and 1 to set desired OFF time. Press and hold button to
advance setting rapidly. Press SET or PAUSE when desired
programmed time is on the display. Or, wait 8 seconds until display
stops flashing to lock in programmed time.
9.
IMPORTANT NOTE: Both an ON and an OFF time MUST be set for
the unit to function correctly.
10.
Press START/STOP to begin timing. Red light will continue to flash
during ON/OFF timing. Equipment only has power during ON timing.
11.
Bar "—" on display appears above ON when ON-timing is in progress.
Bar "—" appears above OFF when OFF-timing is in progress.
12.
Unit will continue to repeat ON/OFF programmed timing. To stop
timing, press START/STOP. Elapsed time returns to 00.00. Red light
stops flashing and is continuously ON.
13.
Press and hold the buttons 1, 2, 3 and 4 simultaneously for 3 seconds
to lock in a set time. A “
” will appear in the lower left-hand corner
of the display. Repeat this step to unlock the set time.
NOTE: When the “
” is on the display, the set time cannot be
changed, even by pressing the RST key.
TIME-OUT
Press PAUSE to stop timing. Press PAUSE again to resume timing. Any
number of time-outs may be taken during a timing.
NOTE
Pressing START/STOP while time is running will stop timing and return count
up display to 00.00.
NOTE
1.
If electrical power is interrupted at any time, unit will turn OFF. Internal
rechargeable battery will continue to light display.
2.
During any interruption of electrical power, count up time elapsed will
return to 00.00. Programmed time will remain on display.
3.
After power is restored, to re-activate unit and re-start programmed
ON/OFF timing, press START/STOP.
TROUBLESHOOTING: Make certain both an ON and an OFF time are
programmed. Unit will not function with only an ON time programmed.
WARRANTY, SERVICE, OR RECALIBRATION
For warranty, service, or recalibration, contact:
CONTROL COMPANY
4455 Rex Road
Friendswood, Texas 77546 USA
Ph. 281-482-1714 Fax 281-482-9448
E-mail sales@control3.com
www.control3.com
Control Company is ISO 9001 Quality-
Certified by DNV and ISO 17025 accredited
as a Calibration Laboratory by A2LA.